Replaced
by:
R6250SD Heat Stress
Meter Datalogger
|
REED
SD-2010
Datalogging Heat Stress Meter
DISCONTINUED
- Replaced by >>
R6250SD
Datalogger with
date/time stamp stores measurements on SD memory card without the
need for software.
This heat stress datalogger measures
temperature, humidity, and direct or radiant sunlight with Wet Bulb
Globe Temperature (WBGT). With this information the SD-2010
determines the "What it feels like" temperature.
The
SD-2010 is OSHA recommended and also features a
user-adjustable WBGT audible alarm and the ability to adjust
settings for indoor temperature measurement.
Using a SD card (max 16Gb), a user can select
a desired sampling rate and quickly generate an Excel file on a SD
card without the use of software. Optional accessories include a
tripod and AC adapter for continuous long-term monitoring. Optional
PC software also allows a user to track live measurements.
|
Features:
-
Wet Bulb Globe Temperature (WBGT) considers the effects of temperature, humidity and direct or radiant sunlight
-
In/Out function displays the WBGT value with or
without direct sun exposure
-
Black Globe Temperature (TG) monitors the
effects of direct solar radiation on
an exposed surface
-
Also measures humidity, wet bulb, dew point and
air temperatures
-
User adjustable WBGT threshold with audible
alarm if threshold is exceeded
-
Data hold and Max/Min record
-
Real time SD memory card datalogger
(memory card optional)
with
built-in clock and calendar
No extra software needed, just plug the SD card
into the computer and it downloads directly to EXCEL
RS-232 and USB computer interface
LCD with backlight displays temperature in °C or °FIncludes brass black globe with sensor
and soft carrying case
NIST Traceable Certification
Available
Specifications:
- Humidity Range: 5 to 95% RH
Accuracy: ≥70% RH: ±(3% rdg + 1% RH);
<70% RH: ±3% RH
- Air Temp. Range: 0 to 50°C (32 to
122°F)
Accuracy: ±0.8°C (±1.5°F)
- Dew Point Temp. Range:
-25.3 to 48.9°C (-13.5 to 120.1°F)
- Wet Bulb Temp. Range:
-21.6 to 50.0°C (-6.9 to
122.2°F)
- Black Globe Temp. Range:
0 to 80°C (32 to 176°F)
Accuracy:
±0.6°C (±1.1°F) - WBGT Temp. Range:
Indoor: 0 to 59°C (32 to 138°F);
- Outdoor: 0 to 56°C (32 to 132°F)
-
Accuracy:
Indoor: ±1°C (±1.8°F);
Outdoor: ±1.5°C (±2.7°F) - Auto Sampling Time:
1, 2, 5, 10, 30, 60, 120,
300, 600, 1800, 3600 seconds
-
Memory Card: SD memory card, 1 GB to 16 GB
(optional)
- Power Supply:
6 x AA 1.5V UM3 batteries
-
Dimensions: Unit: 7.0 x 2.7 x 1.9 in.
Black Ball: 2.95 in.
dia. - Weight: 1.13lb
|
Spec Sheet
(PDF)
SD-2010 Heat
Stress Meter Datalogger
RD-SD-2010
DISCONTINUED |
|
|
|
SD-2010 Heat
Stress Meter w/ NIST
RD-SD-2010-NIST
DISCONTINUED |
|
|
|
|